Tool Changers
Series WMR2000

  • Permanent electromagnet
    The permanent electromagnet in the NC version ensures a secure hold, even if there is a power failure.
  • Integrated media transmission
    Up to four integrated compressed air/vacuum transmitters possible. In addition, secure signal transmission is ensured by specially developed and sealed spring pin contacts.
  • Resistant materials
    The tool changer was designed in accordance with GMP (Good Manufacturing Practice) and ISO 14644 and relies exclusively on FDA-compliant materials to ensure reduced particle emissions. Durable surfaces and materials guarantee resistance to aggressive cleaning agents such as hydrogen peroxide (H2O2) and many others.
Series features
  • Protected against corrosion
  • IO-Link
  • Digital I/O
  • Cleanroom-certified
  • FDA-compliant materials
  • H2O2 resistant materials
  • IP68
  1. Certifications
    • Developed and constructed in accordance with GMP Class A
    • H2O2-resistant materials
    • TÜV-certified cleanroom class
  2. Drive
    • Permanent electromagnet (NC version)
    • Secure hold even in the event of a power failure
  3. Robot flange
    • partial mounting circle in accordance with EN ISO 9409-1
  4. Integrated air feed-through
    • Air / vaccum transfer
    • Hoseless control possible
  5. Integrated current and signal transmission
    • Sealed FDA-compliant spring contacts
    • Integrated loose part coding
  6. Loose part
    • For tool side assembly
    • Sealed flange
  7. Fix part
    • For robot side assembly
    • Sealed flange